Simulating acceleration from stereophotogrammetry for medical device design
Tresadern, P, Thies, SB, Kenney, LPJ, Howard, D, Smith, C, Rigby, J and Goulermas, JY 2009, 'Simulating acceleration from stereophotogrammetry for medical device design' , Journal Of Biomechanical Engineering, 131 (6) .
Full text not available from this repository. (Request a copy)Abstract
When designing a medical device based on lightweight accelerometers, the designer is faced with a number of questions in order to maximize performance while minimizing cost and complexity: Where should the inertial unit be located? How many units are required? How is performance affected if the unit is not correctly located during donning? One way to answer these questions is to use position data from a single trial, captured with a nonportable measurement system (e.g., tereophotogrammetry) to simulate measurements from multiple accelerometers at different locations on the body. In this paper, we undertake a thorough investigation into the applicability of these simulated acceleration signals via a series of interdependent experiments of increasing generality. We measured the dynamics of a reference coordinate frame using stereophotogrammetry over a number of trials. These dynamics were then used to simulate several “virtual” accelerometers at different points on the body segment. We then compared the simulated signals with those directly measured to evaluate the error under a number of conditions. Finally, we demonstrated an example of how simulated signals can be employed in a system design application. In the best case, we may expect an error of 0.028 m/ s2 between a derived virtual signal and that directly measured by an accelerometer. In practice, however, using centripetal and tangential acceleration terms (that are poorly estimated) results in an error that is an order of magnitude greater than the baseline. Furthermore, nonrigidity of the limb can increase error dramatically, although the effects can be reduced considerably via careful modeling. We conclude that using simulated signals has definite benefits when an appropriate model of the body segment is applied.
| Item Type: | Article |
|---|---|
| Themes: | Subjects / Themes > R Medicine > R Medicine (General) Health and Wellbeing |
| Schools: | Colleges and Schools > College of Health & Social Care > School of Health Sciences > Centre for Health, Sport & Rehabilitation Sciences Research Colleges and Schools > College of Health & Social Care Colleges and Schools > College of Health & Social Care > School of Health Sciences Colleges and Schools > College of Science & Technology > School of Computing, Science and Engineering > CASE Control & Systems Engineering Research Centre |
| Journal or Publication Title: | Journal Of Biomechanical Engineering |
| Publisher: | American Society of Mechanical Engineers |
| Refereed: | Yes |
| ISSN: | 0148-0731 |
| Depositing User: | SBA Thies |
| Date Deposited: | 04 Jan 2011 14:47 |
| Last Modified: | 27 Sep 2011 11:41 |
| URI: | http://usir.salford.ac.uk/id/eprint/12649 |
Actions (login required)
| Edit record (repository staff only) |

Tools
Tools