Gonad dose in AP pelvis radiography: impact of anode heel orientation

Mraity, H, England, A and Hogg, P 2016, 'Gonad dose in AP pelvis radiography: impact of anode heel orientation' , Radiography .

[img] PDF - Accepted Version
Restricted to Repository staff only until 22 June 2017.

Download (616kB) | Request a copy
[img] Microsoft Word - Accepted Version
Restricted to Repository staff only

Download (535kB) | Request a copy


Purpose: For antero posterior (AP) pelvis radiographic examination, determine the impact of anode heel orientation on female / male gonad dose. Methods: High sensitivity thermo-luminescent dosimeters (TLDs) were used with an ATOM dosimetry phantom; the phantom was positioned for AP pelvis. TLDs were placed into the testes and ovaries. Radiation dose received by these organs was measured with the feet toward anode and feet toward the cathode. kVp, mAs and SID were manipulated to generate a range of exposures. A dose profile was also generated using Unfors Mult-O-Meter 401 along the long axis of the phantom. Results: A decrease in dose from the central ray toward the anode was noted, with a marked increase toward the cathode. A significant reduction in dose was received by the testes with feet towards the anode compared with feet towards cathode (P˂0.001). No difference was seen for ovarian dose (P˃0.05). kVp, mAs and SID all have an effect on male and female gonad dose. Conclusion: For male pelvis imaging, placing feet towards the anode can be used as a simple dose reduction method.

Item Type: Article
Schools: Schools > School of Health Sciences > Centre for Health Sciences Research
Journal or Publication Title: Radiography
Publisher: Elsevier
ISSN: 1078-8174
Related URLs:
Funders: Non funded research
Depositing User: P Hogg
Date Deposited: 09 Jun 2016 07:36