The influence of shape and sliding distance of femoral head movement loci on the wear of acetabular cups in total hip arthroplasty

Bennett, D, Orr, JF, Beverland, DE and Baker, RJ ORCID: https://orcid.org/0000-0003-4759-4216 2002, 'The influence of shape and sliding distance of femoral head movement loci on the wear of acetabular cups in total hip arthroplasty' , Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 216 (6) , pp. 393-402.

[img] PDF - Published Version
Restricted to Repository staff only

Download (429kB) | Request a copy

Abstract

Wear of the polyethylene acetabular component is the most serious threat to the longterm success of total hip replacements (THRs). Greatly reduced wear rates have been reported for unidirectional, compared to multidirectional, articulation in vitro. This study considers the multidirectional motions experienced at the hip joint as described by movement loci of points on the femoral head for individual THR patients. A three-dimensional computer program determined the movement loci of selected points on the femoral head for THR patients and normal subjects using kinematic data obtained from gait analysis. The sizes and shapes of these loci were quantified by their sliding distances and aspect ratios with substantial differences exhibited between individual THR patients. The average sliding distances ranged from 10.0 to 18.1 mm and the average aspect ratios of the loci ranged from 2.5 to 9.2 for the THR patients. Positive correlations were found between wear rate and average sliding distance, the inverse of the average aspect ratio of the loci and the product of the average sliding distance and the inverse of the average aspect ratio of the loci. Patients with a normal hip joint range of motion produce multidirectional motion loci and tend to experience more wear than patients with more unidirectional motion loci. Differing patterns of multidirectional motion at the hip joint for individual THR patients may explain widely differing wear rates in vivo.

Item Type: Article
Themes: Health and Wellbeing
Schools: Schools > School of Health Sciences
Journal or Publication Title: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Publisher: Professional Engineering Publishing (Institution of Mechanical Engineers)
Refereed: Yes
ISSN: 0954-4119
Depositing User: RH Shuttleworth
Date Deposited: 07 Jul 2011 09:26
Last Modified: 16 Feb 2022 11:47
URI: https://usir.salford.ac.uk/id/eprint/16571

Actions (login required)

Edit record (repository staff only) Edit record (repository staff only)

Downloads

Downloads per month over past year