Effect of rocker shoe design features on forefoot plantar pressures in people with and without diabetes

Chapman, JD, Preece, SJ ORCID: https://orcid.org/0000-0002-2434-732X, Braunstein, B, Höhne, A, Nester, CJ ORCID: https://orcid.org/0000-0003-1688-320X, Brueggemann, G and Hutchins, SW 2013, 'Effect of rocker shoe design features on forefoot plantar pressures in people with and without diabetes' , Clinical Biomechanics, 28 (6) , pp. 679-685.

[img]
Preview
PDF - Accepted Version
Download (387kB) | Preview
[img] Microsoft Word - Accepted Version
Download (573kB)

Abstract

Background: There is no consensus on the precise rocker shoe outsole design that will optimally reduce plantar pressure in people with diabetes. This study aimed to understand how peak plantar pressure is influenced by systematically varying three design features which characterise a curved rocker shoe: apex angle, apex position and rocker angle. Methods: A total of 12 different rocker shoe designs, spanning a range of each of the three design features, were tested in 24 people with diabetes and 24 healthy participants. Each subject also wore a flexible control shoe. Peak plantar pressure, in four anatomical regions, was recorded for each of the 13 shoes during walking at a controlled speed. Findings: There were a number of significant main effects for each of the three design features, however, the precise effect of each feature varied between the different regions. The results demonstrated maximum pressure reduction in the 2nd-4th metatarsal regions (39%) but that lower rocker angles (<20°) and anterior apex positions (> 60% shoe length) should be avoided for this region. The effect of apex angle was most pronounced in the 1st metatarsophalangeal region with a clear decrease in pressure as the apex angle was increased to 100°. Interpretation: We suggest that an outsole design with a 95° apex angle, apex position at 60% of shoe length and 20° rocker angle may achieve an optimal balance for offloading different regions of the forefoot. However, future studies incorporating additional design feature combinations, on high risk patients, are required to make definitive recommendations.

Item Type: Article
Themes: Health and Wellbeing
Schools: Schools > School of Health and Society > Centre for Health Sciences Research
Journal or Publication Title: Clinical Biomechanics
Publisher: Elsevier
Refereed: Yes
ISSN: 0268-0033
Related URLs:
Funders: European Commission Seventh Framework Programme (FP7)
Depositing User: JD Chapman
Date Deposited: 17 Jun 2013 13:49
Last Modified: 16 Feb 2022 15:02
URI: https://usir.salford.ac.uk/id/eprint/29330

Actions (login required)

Edit record (repository staff only) Edit record (repository staff only)

Downloads

Downloads per month over past year