The accuracy of Cobb angle measurement on CT scan projection radiograph images

Alrehily, F, Hogg, P ORCID: https://orcid.org/0000-0002-6506-0827, Twiste, M ORCID: https://orcid.org/0000-0003-2724-3283, Johansen, S and Tootell, AK ORCID: https://orcid.org/0000-0002-8567-8659 2020, 'The accuracy of Cobb angle measurement on CT scan projection radiograph images' , Radiography, 26 (2) , e73-e77.

[img] PDF - Accepted Version
Restricted to Repository staff only until 20 November 2020.
Available under License Creative Commons Attribution Non-commercial No Derivatives 4.0.

Download (280kB) | Request a copy

Abstract

Introduction: Adolescent idiopathic scoliosis (AIS) is a spinal deformity that can affect young children. It requires frequent exposure to X-rays to monitor the deformity, which can lead to the development of radiation-induced cancer later in life. The aim of this study is to test the accuracy of using scan projection radiography (SPR) in computed tomography (CT) scans for AIS assessment. This scanning mode delivers low radiation compared with conventional radiography.
Method: A bespoke phantom with a 14°scoliotic spine was scanned in CT SPR mode using 18 imaging acquisitions. These images were visually evaluated against set criteria to determine their suitability for Cobb angle measurements Those deemed of insufficient quality were excluded from the study (n=8, excluded). Cobb angle measurements were then performed on the remaining images (n=10, included) by 13 observers.
Results: On average, the difference between the measured Cobb angle andthe known angle was –2.75°(SD 1.46°). The agreement between the observers was good (p = 0.861, 95% CI 0.70-0.95)and comparable to similar studies on other imaging modalities which are used for Cobb angle estimation.
Conclusion: CT SPR images can be usedfor AIS assessment with the 5°margin of error that is clinically acceptable.
Implications for practice: The outcome is promising for patients and health providers because it provides an opportunity to reduce patient dose, achieve clinically acceptable Cobb angle measurements whilst using existing (CT) technology that is available in most hospital.

Item Type: Article
Schools: Schools > School of Health and Society
Journal or Publication Title: Radiography
Publisher: Elsevier
ISSN: 1078-8174
Related URLs:
Depositing User: AK Tootell
Date Deposited: 13 Nov 2019 14:16
Last Modified: 06 Apr 2020 11:30
URI: http://usir.salford.ac.uk/id/eprint/53027

Actions (login required)

Edit record (repository staff only) Edit record (repository staff only)

Downloads

Downloads per month over past year