Wilson, S and Thompson, JD ORCID: https://orcid.org/0000-0002-4786-7379
2020,
'Comparison of two Meglumine-Diatrizoate based bowel preparations for computed tomography colonography : comparison of patient symptoms and bowel preparation quality'
, Radiography, 26 (4)
, e290-e296.
|
PDF
- Accepted Version
Available under License Creative Commons Attribution Non-commercial No Derivatives 4.0. Download (535kB) | Preview |
|
![]() |
PDF
- Published Version
Restricted to Repository staff only Download (696kB) | Request a copy |
Abstract
Introduction
To investigate the impact of two Meglumine-Diatrizoate based bowel preparation regimes for computed tomography colonography (CTC) on the patient experience and image quality.
Methods
100 patients consumed Meglumine-Diatrizoate at 24 h and 12 h prior to the CTC examination. 50 patients followed regime 1 (50:50), 50 ml of Meglumine-Diatrizoate at both 24 and 12 h prior to the examination. 50 patients followed regime 2 (75:25), 75 ml of Meglumine-Diatrizoate at 24 h prior to the examination and 25 ml of Meglumine-Diatrizoate at 12 h prior to the examination. All patients completed a questionnaire to indicate the time of onset of adverse effects and when they were most severe. Five advanced practitioners assessed the image quality in a visual grading study. Visual grading characteristic (VGC) analysis was applied with regime 1 as the reference condition and regime 2 and test condition; test alpha was set at 0.05.
Results
Image quality was assessed with successful bowel cleansing as the scoring criteria for the visual grading study. The bowel cleansing as provided by the two Meglumine-Diatrizoate regimes was revealed not to be statistically different, with the area under the VGC curve and 95% confidence intervals 0.487 (0.287, 0.701), p = 0.887. Patients taking the 75:25 bowel preparation experienced a shorter median time to the onset of adverse effects.
Conclusion
There was no observed difference in Image quality criteria score for the two Meglumine-Diatrizoate based bowel preparation with more predictable adverse effects of Meglumine-Diatrizoate with the 75:25 preparation.
Implications for practice
Providing patients with a higher contrast burden 24 h prior to CTC may have a positive impact on the patient experience without compromising image quality.
Item Type: | Article |
---|---|
Schools: | Schools > School of Health and Society > Centre for Health Sciences Research |
Journal or Publication Title: | Radiography |
Publisher: | Elsevier |
ISSN: | 1078-8174 |
Related URLs: | |
Depositing User: | JD Thompson |
Date Deposited: | 05 May 2020 12:37 |
Last Modified: | 16 Feb 2022 04:34 |
URI: | https://usir.salford.ac.uk/id/eprint/56967 |
Actions (login required)
![]() |
Edit record (repository staff only) |