Effects of a modified passive socket system on short-term changes in residuum volume and comfort : a preliminary study in transtibial amputees

Atallah, HM, Kenney, LPJ ORCID: https://orcid.org/0000-0003-2164-3892, Howard, D ORCID: https://orcid.org/0000-0003-1738-0698, Liu, A ORCID: https://orcid.org/0000-0001-9416-1726 and Head, JS ORCID: https://orcid.org/0000-0002-3483-3903 2021, 'Effects of a modified passive socket system on short-term changes in residuum volume and comfort : a preliminary study in transtibial amputees' , Prosthetics and Orthotics International .

[img] PDF - Accepted Version
Restricted to Repository staff only until 11 November 2022.
Available under License Creative Commons Attribution Non-commercial 4.0.

Download (601kB) | Request a copy
Access Information: This is a non-final version of an article published in final form in Atallah, Huthaifa; Kenney, Laurence; Howard, David; Liu, Anmin; Head, John 'Effects of a modified passive socket system on short-term changes in residuum volume and comfort : a preliminary study in transtibial amputees' , Prosthetics and Orthotics International: November 11, 2021 - doi: 10.1097/PXR.0000000000000053

Abstract

Changes in residuum volume are a common problem in lower-limb amputees during prosthesis usage, and can lead to poor suspension, impaired gait, and tissue damage. Residuum volume can be affected by the in-socket air pressure, which will influence fluid flow in and around the residuum. The use of "active" pumps to reduce air pressure has been shown to conserve the residuum volume, but these are expensive and unlikely to be widely available. An alternative, passive approach, based on Boyles' law, is to introduce a larger distal void volume at the end of the socket and hence reduce the change in pressure for a given change in volume. To compare the performance across three test conditions (passive-conventional, with standard distal void; passive-with increased distal void; and active system) in terms of residuum volume changes and comfort. Repeated-measures experiment under three test conditions. Five transtibial amputee participants (three males and two females), aged between 27 and 67 years, and of mobility grade K2 or K3, were fitted with a bespoke test prosthesis that was adapted to include the three test conditions. Residuum volume was measured before and after walking under each test condition (presented in a random order). Comfort was also assessed after walking with each test condition. The reduction in residuum volume, relative to the baseline volume, was higher for the conventional passive system (4.2% ± 2.8%) compared with the modified passive (1.4% ± 1.4%) and active (1.6% ± 1.1%) systems. The use of a passive suspension system with an increased distal void within the socket may help to stabilize the residuum volume during prosthesis usage. [Abstract copyright: Copyright © International Society for Prosthetics and Orthotics 2021.]

Item Type: Article
Additional Information: ** From PubMed via Jisc Publications Router **Journal IDs: eissn 1746-1553 **Article IDs: pubmed: 34772866; pii: 00006479-900000000-99925 **History: published 11-11-2021
Schools: Schools > School of Health and Society
Journal or Publication Title: Prosthetics and Orthotics International
Publisher: Lippincott, Williams & Wilkins
ISSN: 0309-3646
Related URLs:
SWORD Depositor: Publications Router
Depositing User: Publications Router
Date Deposited: 30 Nov 2021 09:09
Last Modified: 15 Feb 2022 17:03