Number of items: 84.
Gardiner, JD, Bari, AZ, Kenney, LPJ, Twiste, M, Moser, D, Zahedi, S and Howard, D
2017,
'Performance of optimised prosthetic ankle designs that are based on a hydraulic variable displacement actuator (VDA)'
, IEEE Transactions on Neural Systems and Rehabilitation Engineering (99)
.
|
|
Costamagna, E, Thies, SBA, Kenney, LPJ, Howard, D, Liu, A and Ogden, D
2017,
'A generalizable methodology for stability assessment of walking aid users'
, Medical Engineering & Physics, 47
, pp. 167-175.
|
|
Gardiner, JD, Bari, AZ, Howard, D and Kenney, LPJ
2017,
'Transtibial amputee gait efficiency : energy storage and return versus solid ankle cushioned heel prosthetic feet'
, Journal of Rehabilitation Research and Development, 53 (6)
, pp. 1133-1138.
|
|
Major, M, Twiste, M, Kenney, L and Howard, D
2017,
'The effects of prosthetic ankle stiffness on stability of gait in people with trans-tibial amputation'
, Journal of Rehabilitation Research and Development, 53 (6)
, pp. 839-852.
|
|
Sun, M ORCID: 0000-0003-1514-1490, Howard, D, Kenney, LPJ, Luckie, HM, Waring, K, Williamson, T, Hardiker, NR, Smith, C, Taylor, P, Finn, S, Merson, E, Sadhoo, A and Nolan, D
2017,
FES-UPP : an advanced functional electrical stimulation system for upper limb rehabilitation
, in: STEM for Britain 2017.
|
![[img]](http://usir.salford.ac.uk/41479/1.hassmallThumbnailVersion/Mingxu%20Sun-3599%20FES-UPP%20abstract%20ACK%20updated.pdf)  Preview |
|
Ahanchian, N, Nester, CJ, Howard, D, Ren, Lei and Parker, DJ
2016,
'Estimating the material properties of heel pad sub-layers using inverse finite element analysis'
, Medical Engineering & Physics, 40
, pp. 11-19.
|
![[img]](http://usir.salford.ac.uk/41291/1.hassmallThumbnailVersion/FINAL%20Manuscript%20marked%20version.pdf)  Preview |
|
Weinert-Aplin, RA, Howard, D, Twiste, M, Jarvis, HL, Bennett, A.N. and Baker, RJ ORCID: 0000-0003-4759-4216
2016,
'Energy flow analysis of amputee walking shows a proximally-directed transfer of energy in intact limbs, compared to a distally-directed transfer in prosthetic limbs at push-off'
, Medical Engineering & Physics, 39
, pp. 73-82.
|
![[img]](http://usir.salford.ac.uk/40766/1.hassmallThumbnailVersion/Power%20Flow%20paper_FOR%20USIR.PDF)  Preview |
|
Sun, M, Howard, D, Kenney, LPJ, Smith, CL, Luckie, HM and Waring, K
2016,
A flexible control system of functional electrical stimulation (FES) for upper limb rehabilitation
, in: Medical Physics & Engineering Conference 2016, 13th - 14th September 2016, Manchester.
|
![[img]](http://usir.salford.ac.uk/40024/1.hassmallThumbnailVersion/A%20Flexible%20Control%20System%20of%20Functional%20Electrical%20Stimulation%20%28FES%29%20for%20Upper%20Limb%20Rehabilitation.pdf)  Preview |
|
Kenney, LPJ, Heller, B, Barker, A, Reeves, M, Healey, J, Good, T, Cooper, G, Sha, N, Prenton, S, Liu, A and Howard, D
2016,
'A review of the design and clinical evaluation of the ShefStim array-based functional electrical stimulation system'
, Medical Engineering & Physics, 38 (11)
, 1159 -1165.
|
|
Sun, M, Kenney, Laurence, Smith, CL, Waring, K, Luckie, HM, Liu, A and Howard, D
2016,
'A novel method of using accelerometry for upper limb FES control'
, Medical Engineering & Physics, 38 (11)
, pp. 1244-1250.
|
|
Sun, M, Kenney, Laurence, Smith, CL, Waring, K, Luckie, HM and Howard, D
2016,
A flexible finite state controller for upper limb functional electrical stimulation
, in: 20th Annual Conference of the International Functional Electrical Stimulation Society, 8-10th June 2016, La Grande-Motte, France.
|
|
Ormerod, MG, Newton, RA, MacLennan, HA, Faruk, M, Thies, SBA, Kenney, LPJ, Howard, D and Nester, CJ
2015,
'Older people’s experiences of using tactile paving'
, Municipal Engineer, 168 (1)
, pp. 3-10.
|
|
Sun, M, Howard, D, Kenney, LPJ, Smith, CL, Waring, K and Luckie, HM
2015,
Novel methods of using accelerometry for upper limb FES control [conference paper]
, in: 5th Conference of the International Functional Electrical Stimulation Society (IFESS) UK & Ireland Chapter : Stimulating Technology for the Future, 8-9 May 2015, Sheffield, UK.
Item not available from this repository.
|
|
Gardiner, JD, Bari, Z, Kenney, Laurence and Howard, D
2015,
Meta-analysis of metabolic cost of amputee walking shows only a marginal improvement in cost when using ESR feet compared to conventional SACH feet
, in: ISPO World Congress 2015, June 2015, Lyon, France.
|
|
Kenney, Laurence, Heller, B, Barker, AT, Reeves, M, Healey, J, Good, T, Cooper, G, Sha, N, Prenton, S and Howard, D
2015,
'The design, development and evaluation of an array-based FES system with automated setup for the correction of drop foot'
, IFAC-PapersOnLine, 48 (20)
, pp. 309-314.
|
|
Parker, DJ, Cooper, G, Pearson, S, Crofts, GS, Howard, D, Busby, P and Nester, CJ
2015,
'A device for characterising the mechanical properties of the plantar soft tissue of the foot'
, Medical Engineering & Physics, 37 (11)
, pp. 1098-1104.
|
![[img]](http://usir.salford.ac.uk/37399/1.hassmallThumbnailVersion/Final%20paper%20downloaded.pdf)  Preview |
|
Smith, C, Kenney, Laurence, Howard, D, Hardiker, NR, Waring, K, Sun, M and Luckie, HM
2015,
A model to predict setup time for a novel upper limb FES system
, in: Fifth Conference of the UK and Ireland Chapter of the International Functional Electrical Stimulation Society (UKRI-IFESS), 8th – 9th May 2015, Sheffield, UK.
|
|
Kenney, Laurence, Taylor, P, Finn, S, Smith, C, Waring, K, Luckie, HM, Hardiker, NR, Williamson, T and Howard, D
2015,
A practical, yet flexible functional electrical stimulation system for upper limb rehabilitation following stroke
, in: Medical technology of the future, 27 January 2016, Manchester, UK.
(Submitted)
|
|
Prenton, S, Kenney, LPJ, Stapleton, C, Cooper, G, Reeves, ML, Heller, BW, Sobuh, M, Barker, AT, Healey, J, Good, TR, Thies, SBA, Howard, D and Williamson, T
2014,
'Feasibility study of a take-home array-based functional electrical stimulation system with automated setup for current functional electrical stimulation users with foot-drop'
, Archives of Physical Medicine and Rehabilitation, 95 (10)
, pp. 1870-1877.
|
|
Head, JS, Heath, GH, Howard, D, Hutchins, SW, Kenney, LPJ and Aksenov, A
2014,
'The use of an adjustable electrode housing unit to compare electrode alignment
and contact variation with myoelectric prosthesis functionality: A pilot study'
, Prosthetics and Orthotics International, 40 (1)
, pp. 123-128.
|
|
Grootveld, L, Thies, SBA, Ogden, D, Howard, D and Kenney, LPJ
2014,
'Automatic detection of lift-off and touch-down of a pick-up walker using 3D kinematics'
, Medical Engineering & Physics, 36 (2)
, pp. 255-260.
|
|
Hu, D, Ren, L, Howard, D and Zong, C
2014,
'Biomechanical analysis of force distribution in human finger extensor mechanisms'
, BioMed Research International, 2014
, pp. 1-9.
|
![[img]](http://usir.salford.ac.uk/style/images/fileicons/application_pdf.png)  Preview |
|
Milanese, S, Hu, D, Howard, D and Ren, L
2014,
'Biomechanical analysis of the human finger extensor mechanism during isometric pressing'
, PLoS ONE, 9 (4)
, e94533.
|
![[img]](http://usir.salford.ac.uk/style/images/fileicons/application_pdf.png)  Preview |
|
Major, MJ, Twiste, M, Kenney, LPJ and Howard, D
2014,
'The effects of prosthetic ankle stiffness on ankle and knee kinematics, prosthetic limb loading, and net metabolic cost of trans-tibial amputee gait'
, Clinical Biomechanics, 29 (1)
, pp. 98-104.
|
|
Melvin, J, Preece, SJ, Nester, CJ and Howard, D
2014,
'An investigation into plantar pressure measurement protocols for footwear research'
, Gait & Posture, 40 (4)
, pp. 682-687.
|
|
Al Qaroot, B, Hogg, P, Twiste, M and Howard, D
2014,
'A systematic procedure to optimise dose and image quality for the measurement of inter-vertebral angles from lateral spinal projections using Cobb and superimposition methods'
, Journal of X-Ray Science and Technology, 22 (5)
, pp. 613-625.
|
![[img]](http://usir.salford.ac.uk/style/images/fileicons/application_pdf.png)  Preview |
|
Aung, M, Thies, SBA, Kenney, LPJ, Howard, D, Selles, R and Findlow, AH
2013,
'Automated detection of instantaneous gait events
using time frequency analysis and manifold embedding'
, IEEE Transactions on Neural Systems and Rehabilitation Engineering, 21 (6)
, pp. 908-915.
|
|
Major, MJ, Howard, D, Jones, R and Twiste, M
2012,
'The effects of transverse rotation angle on compression and effective lever arm of prosthetic feet during simulated stance'
, Prosthetics and Orthotics International, 36 (2)
, pp. 231-235.
|
![[img]](http://usir.salford.ac.uk/42507/1.hassmallThumbnailVersion/Paper%20-%20ExternRot%202017-06-04%20Final%20submission.pdf)  Preview |
|
Major, MJ, Kenney, LPJ, Twiste, M and Howard, D
2012,
'Stance phase mechanical characterization of transtibial prostheses distal to the socket : a review'
, Journal of Rehabilitation Research and Development, 49 (6)
, pp. 815-830.
|
|
Thies, S, Jones, RK, Kenney, LPJ, Howard, D and Baker, RD
2011,
'Effects of ramp negotiation, paving type and shoe sole geometry on toe clearance in young adults'
, Journal of Biomechanics, 44 (15)
, pp. 2679-2684.
|
|
Cooper, G, Barker, AT, Heller, BW, Good, T, Kenney, LPJ and Howard, D
2011,
'The use of hydrogel as an electrode-skin interface for electrode array FES applications'
, Medical Engineering & Physics, 33 (8)
, pp. 967-982.
|
|
Guo, JY, Zheng, YP, Kenney, LPJ, Bowen, A, Howard, D and Canderle, J
2011,
'A comparative evaluation of sonomyography, electromyography, force, and wrist angle in a discrete tracking task'
, Ultrasound in Medicine & Biology, 37 (6)
, pp. 884-891.
|
|
Thies, SB, Kenney, LPJ, Howard, D, Nester, CJ, Ormerod, M, Newton, R, Baker, RD, Faruk, M and Maclennan, HA
2011,
'Biomechanics for inclusive urban design : effects of tactile paving on older adults’ gait when crossing the street'
, Journal of Biomechanics, 44 (8)
, pp. 1599-1604.
|
|
Major, M, Twiste, M, Kenney, LPJ and Howard, D
2011,
'Amputee independent prosthesis properties - a new model for description and measurement'
, Journal of Biomechanics, 44 (14)
, pp. 2572-2575.
|
|
Ren, L, Howard, D, Ren, L, Nester, CJ and Tian, L
2010,
'A generic analytical foot rollover model for predicting translational ankle kinematics in gait simulation studies'
, Journal of Biomechanics, 43 (2)
, pp. 194-202.
|
|
Nester, CJ, Liu, A, Ward, E, Howard, D, Cocheba, J and Derrick, T
2010,
'Error in the description of foot kinematics due to violation of rigid body assumptions'
, Journal of Biomechanics, 43 (4)
, pp. 666-672.
|
|
Cooper, G, Sheret, I, McMillian, L, Siliverdis, K, Sha, N, Hodgins, D, Kenney, LPJ and Howard, D
2009,
'Inertial sensor-based knee flexion/extension angle estimation'
, Journal of Biomechanics, 42 (16)
, pp. 2678-2685.
|
|
Preece, S, Goulermas, JY, Kenney, LPJ, Howard, D, Meijer, K and Crompton, R
2009,
'Activity identification using body-mounted sensors — a review of classification techniques'
, Physiological Measurement, 30
, R1-R33.
|
|
Thies, SB, Tresadern, PA, Kenney, LPJ, Smith, J, Howard, D, Goulermas, JY, Smith, C and Rigby, J
2009,
'Movement variability in stroke patients and controls performing two upper limb functional tasks: a new assessment methodology'
, Journal of NeuroEngineering and Rehabilitation, 6 (2)
.
|
![[img]](http://usir.salford.ac.uk/style/images/fileicons/application_pdf.png)  Preview |
|
Tresadern, P, Thies, SB, Kenney, LPJ, Howard, D, Smith, C, Rigby, J and Goulermas, JY
2009,
'Simulating acceleration from stereophotogrammetry for medical device design'
, Journal Of Biomechanical Engineering, 131 (6)
.
Item not available from this repository.
|
|
Preece, S, Goulermas, JY, Kenney, LPJ and Howard, D
2009,
'A comparison of feature extraction methods for the classification of dynamic activities from accelerometer data'
, IEEE Transactions on Biomedical Engineering, 56
, pp. 871-879.
|
![[img]](http://usir.salford.ac.uk/style/images/fileicons/application_pdf.png)  Preview |
|
Tao, K, Wang, D, Wang, C, Wang, X, Liu, A, Nester, CJ and Howard, D
2009,
'An in vivo experimental validation of a computational model of human foot'
, Journal of Bionic Engineering, 6 (4)
, pp. 387-397.
Item not available from this repository.
|
|
Major, MJ, Twiste, M, Kenney, LPJ and Howard, D
2008,
'Investigating effects of mechanical properties of trans-tibial prostheses on user performance'
, Journal of Biomechanics, 41 (S1)
, p. 416.
Item not available from this repository.
|
|
Sha, N, Kenney, LPJ, Heller, BW, Barker, AT, Howard, D and Wang, W
2008,
'The effect of the impedance of a thin hydrogel electrode on sensation during functional electrical stimulation'
, Medical Engineering & Physics, 30 (6)
, pp. 739-746.
Item not available from this repository.
|
|
Findlow, AH, GOULERMAS, J, Nester, CJ, Howard, D and Kenney, LPJ
2008,
'Predicting lower limb joint kinematics using wearable motion sensors'
, Gait & Posture, 28 (1)
, pp. 120-126.
|
|
Tresadern, P, Thies, SB, Kenney, LPJ, Howard, D and Goulermas, JY
2008,
'Rapid prototyping for functional electrical stimulation control'
, IEEE Pervasive Computing, 7 (2)
, pp. 62-69.
Item not available from this repository.
|
|
Sha, N, Kenney, LPJ, Heller, B, Barker, AT, Howard, D and Moatamedi, M
2008,
'A finite element model to identify electrode influence on current distribution in the skin'
, Artificial Organs, 32 (8)
, pp. 639-643.
|
![[img]](http://usir.salford.ac.uk/style/images/fileicons/application_pdf.png)  Preview |
|
Preece, SJ, Graham-Smith, P, Nester, CJ, Howard, D, Hermens, H, Herrington, LC and Bowker, P
2008,
'The influence of gluteus maximus on transverse plane tibial rotation'
, Gait & Posture, 27
, pp. 616-621.
|
|
Goulermas, JY, Findlow, AH, Nester, CJ, Liatsis, P, Zeng, XJ, Kenney, LPJ, Tresadern, P, Thies, SB and Howard, D
2008,
'An instance-based algorithm with auxiliary similarity information for the estimation of gait kinematics from wearable sensors.'
, IEEE Transactions on Neural Networks, 19 (9)
, pp. 1574-1582.
Item not available from this repository.
|
|
Nester, CJ, Liu, A, Ward, E, Howard, D, Cocheba, J, Derrick, T and Patterson, P
2007,
'In vitro study of foot kinematics using a dynamic walking cadaver model'
, Journal of Biomechanics, 40 (9)
, pp. 1927-1937.
Item not available from this repository.
|
|
Arndt, A, Nester, CJ, Howard, D, Liu, A, Wolf, P, Lundberg, A, Jones, RK, Stacoff, A and Lundgren, P
2007,
'Foot kinematics during walking measured using bone and surface mounted markers'
, Journal of Biomechanics, 40 (15)
, pp. 3412-3423.
Item not available from this repository.
|
|
Arndt, A, Stacoff, A, Wolf, P, Nester, CJ, Liu, A, Jones, R, Howard, D and Lundberg, A
2007,
'Intrinsic foot kinematics measured in vivo during the stance phase of slow running'
, Journal of Biomechanics, 40 (12)
, pp. 2672-2678.
Item not available from this repository.
|
|
Ren, L, Jones, RK, Liu, A, Nester, CJ and Howard, D
2007,
Assessment of 3D dynamic interactions between backpack and bearer using accelerometers and gyroscopes
, in: International Society of Biomechanics Congress, 2nd-5th July 2007, Taipei.
Item not available from this repository.
|
|
Nester, CJ, Jones, RK, Liu, A, Howard, D, Lundberg, A, Arndt, A, Lundgren, P, Stacoff, A and Wolf, P
2007,
'Foot kinematics during walking measured using bone and surface mounted markers'
, Journal of Biomechanics, 40 (Supp.2)
, S95.
Item not available from this repository.
|
|
Nester, CJ, Jones, RK, Liu, A, Howard, D, Lundberg, A, Arndt, A, Lundgren, P, Stacoff, A and Wolf, P
2007,
Foot kinematics during walking measured using bone and surface mounted markers
, in: Salford’s 4th International Conference on Biomechanics of the Lower Limb in Health Disease and Rehabilitation, 3rd-5th September 2007, Salford.
Item not available from this repository.
|
|
Nester, CJ, Jones, RK, Liu, A, Howard, D, Lundberg, A, Arndt, A, Lundgren, P, Stacoff, A and Wolf, P
2007,
Foot kinematics during walking measured using bone and surface mounted markers
, in: International Society of Biomechanics Congress, 2nd-5th July 2007, Taipei.
Item not available from this repository.
|
|
Major, MJ, Twiste, M, Kenney, LPJ and Howard, D
2007,
'Novel method of quantifying mechanical properties of trans-tibial prostheses'
, Journal of Biomechanics, 40 (S2)
, p. 595.
|
|
Arndt, A, Wolf, P, Nester, CJ, Liu, A, Jones, R, Howard, D, Stacoff, A, Lundgren, P and Lundberg, A
2006,
'Intrinsic foot motion measured in vivo during barefoot running'
, Journal of Biomechanics, 39 (Supp.1)
, S182.
Item not available from this repository.
|
|
Nester, CJ, Jones, R, Liu, A, Howard, D, Lundberg, A, Arndt, T, Lundgren, P, Stacoff, A and Wolf, P
2006,
'Invasive study of rearfoot, midfoot and forefoot kinematics during walking'
, Journal of Biomechanics, 39 (Supp.1)
, S77.
Item not available from this repository.
|
|
Arndt, A, Wolf, P, Nester, CJ, Liu, A, Jones, RK, Howard, D, Stacoff, A, Lundgren, P and Lundberg, A
2006,
Intrinsic foot motion measured in vivo during barefoot running
, in: 5th World Congress of Biomechanics, 29th July - 4th August 2006, Munich.
Item not available from this repository.
|
|
Nester, CJ, Jones, RK, Liu, A, Howard, D, Lundberg, A, Arndt, T, Lundgren, P, Stacoff, P and Wolf, P
2006,
Invasive study of rearfoot, midfoot and forefoot kinematics during walking
, in: 5th World Congress of Biomechanics, 29th July - 4th August 2006, Munich.
Item not available from this repository.
|
|
Goulermas, JY, Findlow, AH, Nester, CJ, Howard, D and Bowker, P
2005,
'Automated design of robust discriminant analysis classifier for foot pressure lesions using kinematic data'
, IEEE Transactions on Biomedical Engineering, 52 (9)
, pp. 1549-1562.
|
![[img]](http://usir.salford.ac.uk/style/images/fileicons/application_pdf.png)  Preview |
|
Liu, A, Nester, CJ, Ward, E, Howard, D, Cocheba, J, Derrick, T and Patterson, P
2005,
In vivo study of foot kinematics using a walking simulator
, in: ISB XXth Congress-ASB 29th Annual Meeting, July - 5th August 2005, Cleveland, Ohio.
Item not available from this repository.
|
|
Liu, A, Nester, CJ, Ward, E, Howard, D, Cocheba, J, Derrick, T and Patterson, P
2005,
In vivo study of foot kinematics using a walking simulator
, in: Salford’s 3rd International Conference on Biomechanics of the Lower Limb in Health Disease and Rehabilitation, 5th-7th September 2005, Salford.
Item not available from this repository.
|
|
Liu, A, Nester, CJ, Ward, E, Howard, D, Derrick, T, Cocheba, J and Patterson, P
2004,
Development of an improved rigid body model of the foot
, in: Foot and Ankle Retreat II, 30th April - 1st May 2004, Los Angeles, USA.
Item not available from this repository.
|
|
Liu, A, Nester, CJ, Ward, E, Howard, D, Derrick, T, Cocheba, J and Patterson, P
2004,
'Development of an improved rigid body of the foot'
, Journal of Orthopaedic and Sports Physical Therapy, 34 (9)
.
Item not available from this repository.
|
|
Liu, A, Nester, CJ, Ward, E, Howard, D, Derrick, T, Cocheba, J and Patterson, P
2004,
Dynamic cadaver model for a new understanding of rigid body foot kinematics
, in: International Society for Prosthetics and Orthotics, August 2004, Hong Kong.
Item not available from this repository.
|
|
Jiang, W, Liu, A and Howard, D
2001,
Foot-force distribution in legged robots
, in: CLAWAR : 4th International Conference on Climbing and Walking Robots, September 2001, Karlsruhe.
Item not available from this repository.
|
|
Al-Qaroot, B, McAloon, MT, Howard, D, Hogg, P and Twiste, M
The effect of body fat percentage on inter-vertebral spinal mobility control from hyper-extension spinal orthoses.
, in: The UK National Member Society’s Annual Scientific Meeting of the International Society for Prosthetics & Orthotics, 04 - 05 Nov 2010., Newcastle, UK,.
Item not available from this repository.
|
|
Smith, CL, Kenney, Laurence, Howard, D, Waring, K, Sun, M and Hardiker, NR
The relationship between impairment, functional ability, hand-arm task complexity and set-up difficulty for an Advanced FES Rehab Tool
, in: Fourth Conference of the UK and Ireland Chapter of the International Functional Electrical Stimulation Society (IFESSUKI), 12-13 April 2013, Southampton, UK.
|
|
This list was generated on Wed Apr 25 06:56:27 2018 UTC.